Breathing Simulator

ASL 5000® Breathing Simulator

The ASL 5000® is the world’s most sophisticated breathing simulator, and capable of simulating the full range of patients – neonatal to adult. The ASL 5000® is able to breathe spontaneously even while being ventilated and can be used with any ventilator (and any ventilator mode). The ASL 5000® can help you save time, accelerate development and gain better control of testing protocols.

Intended Use

This highly accurate, versatile instrument represents the premier choice for product development and testing for ventilators, CPAP, aerosol drug delivery and other respiratory therapy devices. Review this list of research studies using the ASL 5000® to learn about how others are using the ASL 5000®.

Key Features

ASL 5000® Lung Solution

The ASL 5000® Lung Solution, developed in collaboration with Laerdal, allows you to integrate the world’s most realistic breathing simulator, the ASL 5000®, with the:

Now you can use your SimMan®, Nursing Anne Simulator or SimBaby™ to conduct high-fidelity ventilation management training in anesthesia, critical care, emergency medicine, pulmonology, respiratory care, and pediatric care.

One ASL 5000®, Multiple Configurations

QuickLung Breather

The QuickLung® Breather is an effective tool to simulate a spontaneously breathing patient, at an affordable price! Based on the IngMar Medical QuickLung or QuickLung Jr., the QuickLung Breather opens up new opportunities to demonstrate and test ventilator triggering and important modes of ventilation such as SIMV, Pressure Support and PAV.

Intended Use

Ventilator management training, demonstration, and testing with no risk to patients! 

Quickly create a patient scenario

Simulate a variety of patient types with variable settings

Upgrade your existing QuickLung in seconds. The QuickLung can be easily mounted and detached from the Breather for maximum versatility.

QuickLung

Quick Lung

QuickLung® is an adjustable, precision test lung for ventilator testing and training. It is compact, easy-to-use, and capable of simulating a wide range of patient conditions, including patient inspiratory efforts. QuickLung is available in a an adult or pediatric model, both in calibrated or standard versions. Learn more in the “Options” section below. You can use QuickLung alone, or customize according to your needs by adding functions such as spontaneous breathing. Compatible with all ventilators, from ICU to transport.

Intended Use

Key Features

Linear Test Lung

Linear Test Lung (LTL) is a passive test lung that produces a linear compliance curve and realistic inflection points throughout a range of settings.  It performs more like a real patient than other bag-style lungs, maintaining a smooth response to progressive inflation, without any “hiccups” due to bulging-out of the bag.

Intended Use

Ventilator testing and in-service training

Realistic

Produces a linear compliance curve and realistic inflection points throughout a range of settings

Adjustable Compliance

Simulates patients with compliances of C10, C30, C60 (approximate)

Impressive Value

Priced significantly below similar bag-style test lungs, while providing impressive performance
linear-test-lung

Parabolic Resistor Ring

The Parabolic Resistor Ring is a set of 7 switch-selectable calibrated respiratory resistance orifices (Rp5-Rp500) integrated into a 4″ diameter ring. A calibration certificate is available for standards testing.

Intended Use

Ventilator testing to ISO 10651 and ASTM F1100

Simulation, respiratory education

ASL 5000® Breathing Simulator

The ASL 5000® is the world’s most sophisticated breathing simulator, and capable of simulating the full range of patients – neonatal to adult. The ASL 5000® is able to breathe spontaneously even while being ventilated and can be used with any ventilator (and any ventilator mode). The ASL 5000® can help you save time, accelerate development and gain better control of testing protocols.

Intended Use

This highly accurate, versatile instrument represents the premier choice for product development and testing for ventilators, CPAP, aerosol drug delivery and other respiratory therapy devices. Review this list of research studies using the ASL 5000® to learn about how others are using the ASL 5000®.

Key Features

  • Perform long term testing on all ventilator modes with virtually any patient type
  • Develop adaptive algorithms on ventilators
  • Simulate patient breathing associated with sleep apnea for development of CPAP devices
  • Evaluate aerosol drug delivery devices using realistic high-flow inhalation
  • Compare ventilators or ventilator modes (e.g. pressure support mode) on the same reproducible patient
  • Create repeatable breath patterns at a high level of accuracy for respiratory device product development with the smart pump

ASL 5000® Lung Solution

The ASL 5000® Lung Solution, developed in collaboration with Laerdal, allows you to integrate the world’s most realistic breathing simulator, the ASL 5000®, with the:

  • SimMan® portfolio
  • Nursing Anne Simulator
  • SimBaby™

Now you can use your SimMan®, Nursing Anne Simulator or SimBaby™ to conduct high-fidelity ventilation management training in anesthesia, critical care, emergency medicine, pulmonology, respiratory care, and pediatric care.

One ASL 5000®, Multiple Configurations

  • Manage both the ASL 5000®, SimMan®, Nursing Anne Simulator or SimBaby™ directly from LLEAP, the Laerdal Learning Application
  • Connect the ASL 5000® to the manikin for fully immersive training, interdisciplinary training and competency evaluations
  • Connect the ASL 5000® directly to the ventilator and connect to Virtual Manikin for demonstrating specific interactions, new hire, and new ventilator onboarding

QuickLung Breather

The QuickLung® Breather is an effective tool to simulate a spontaneously breathing patient, at an affordable price! Based on the IngMar Medical QuickLung or QuickLung Jr., the QuickLung Breather opens up new opportunities to demonstrate and test ventilator triggering and important modes of ventilation such as SIMV, Pressure Support and PAV.

Intended Use

Ventilator management training, demonstration, and testing with no risk to patients! 

Quickly create a patient scenario

  • Select a breathing mode (Eupnea, Cheyne-Stokes, Biot’s, Kussmaul or Apneusis)
  • Customize parameters (breath rate, volume, I:E ratio)
  • See how to set up patient examples: ARDS, ventilator dysynchrony (breath stacking) pediatric ARDS, pediatric asthma exacerbation, COPD

Simulate a variety of patient types with variable settings

  • Correspond to IEC ventilator performance standards);
  • Resistance (5, 20, 50 cmH2O/L/s)
  • Compliance (50, 20, 10 mL/cm H2O)

Upgrade your existing QuickLung in seconds. The QuickLung can be easily mounted and detached from the Breather for maximum versatility.

Quick Lung

QuickLung® is an adjustable, precision test lung for ventilator testing and training. It is compact, easy-to-use, and capable of simulating a wide range of patient conditions, including patient inspiratory efforts. QuickLung is available in a an adult or pediatric model, both in calibrated or standard versions. Learn more in the “Options” section below. You can use QuickLung alone, or customize according to your needs by adding functions such as spontaneous breathing. Compatible with all ventilators, from ICU to transport.

Intended Use

  • Ventilator performance verification: combine with any flow/volume/ pressure analyzer for a complete ventilator testing system
  • In-service training and sales demonstration
  • Basic mechanical ventilation training

Key Features

  • Compact 7.5” x 11” footprint. Works accurately from a table or suspended from a ventilator.
  • Ventilator triggering: Detachable QuickTrigger® feature simulates a physiologically-correct inspiratory effort (negative pressure).
  • Versatile: QuickLung is the core of a modular system with options for a variety of applications.

Linear Test Lung

Linear Test Lung (LTL) is a passive test lung that produces a linear compliance curve and realistic inflection points throughout a range of settings.  It performs more like a real patient than other bag-style lungs, maintaining a smooth response to progressive inflation, without any “hiccups” due to bulging-out of the bag.

Intended Use

Ventilator testing and in-service training

Realistic

Produces a linear compliance curve and realistic inflection points throughout a range of settings

Adjustable Compliance

Simulates patients with compliances of C10, C30, C60 (approximate)

Impressive Value

Priced significantly below similar bag-style test lungs, while providing impressive performance

Parabolic Resistor Ring

The Parabolic Resistor Ring is a set of 7 switch-selectable calibrated respiratory resistance orifices (Rp5-Rp500) integrated into a 4″ diameter ring.  A calibration certificate is available for standards testing.

Intended Use

Ventilator testing to ISO 10651 and ASTM F1100

Simulation, respiratory education

Quick Navigation