ECG & EEG Test Solutions

HRS200 - Heart rate simulator

Key Specification :-

CMRR 2.0 - ECG Common Mode Rejection Ratio Tester

ECG related standards such as IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, AAMI EC13… require a common mode rejection ratio test (CMRR). And CMRR is one of the more complex tests in the standard. 

Key Specification :-

MECG 2.0 - Multichannel ECG Test System

ECG database generator for Diagnostic and Ambulatory ECG – Support IEC60601-2-25, -2-47 and AAMI EC57 database tests – Embedded CAL, ANE, Biological, NST waveforms – Allows to upload and playback AHA, MIT, and CU format directly

Key Specification :-

Other Functions

Physionet compatibility

Built in test waveforms

SECG 4.0 - Single Channel ECG Test System

Key Specification :-

Standards

The latest revision of SECG4.0 has been updated in compliance with the latest 2011 and 2012 editions of the ECG standards.

ECG related standards contain a range of “single channel” tests, such as

secg
ecg-set

ECG Set

Features

Benefits

Standards

SECG 5.0 AIO

The ECG simulator designed for ECG performance testing. Capable of adding noise, respiration and lead-off simulations. Flexible operation modes for standalone or PC software.
Suitable for R&D and compliance testing.
Compliant with IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, GB 9706.225, GB 9706.227, YY 9706.247, YY1079, YY1139, YY0782, YY0885, JJG 760, JJG 1042, ANSI/AAMI EC11, ANSI/AAMI EC13

Key Features

cmrr

CMRR 3.0+

The CMRR tester combining accuracy, convenience and test automation all together.
Compliant with IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, IEC 60601-2-26, YY1079, YY1139, YY0782, YY0885, ANSI / AAMI EC11, ANSI / AAMI EC13.
Applicable for R&D, compliance and production line testing.Suitable for R&D and compliance testing.
Compliant with IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, GB 9706.225, GB 9706.227, YY 9706.247, YY1079, YY1139, YY0782, YY0885, JJG 760, JJG 1042, ANSI/AAMI EC11, ANSI/AAMI EC13

Key Features

CMRR 3.0E

The EEG CMRR tester combining accuracy, convenience and test automation all together.
Compliant with IEC80601-2-26:2019 and applicable for R&D, compliance and production run testing.

Key Features

SEEG 100E

The EEG performance tester is compliant with the test requirements of IEC 80601-2-26:2019 and applicable for R&D, compliance and production line testing.

Key Features

AECG100

The Innovative simulator to output ECG and PPG analog signals simultaneously.
Adjustable time difference parameters to generate various Pulse Wave Transit Time (PWTT) signals.
Standard Coverage: IEC 60601-2-47, YY 0885, YY 9706.247.
Applicable for R&D, compliance and production line testing

Key Features

dfs200

DFS200 Defibrillator and AED Tester

It comes with various ECG patterns for AED defibrillation tests and an embedded battery voltage multimeter. The main features are data retrieval and routine creation. It can manage a complete history of every measurement the user has made in the device, including AED test results, date and time, along with user notes. With AIMS CMS for synchronization management, it is responsible for work order viewing, work order tracking, path planning, etc.

Key Features

CMRR 2.0 - ECG Common Mode Rejection Ratio Tester

ECG related standards such as IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, AAMI EC13… require a common mode rejection ratio test (CMRR). And CMRR is one of the more complex tests in the standard. Key specifications :-

MECG 2.0 - Multichannel ECG Test System

– ECG database generator for Diagnostic and Ambulatory ECG – Support IEC60601-2-25, -2-47 and AAMI EC57 database tests – Embedded CAL, ANE, Biological, NST waveforms – Allows to upload and playback AHA, MIT, and CU format directly

SECG 5.0 AIO

The ECG simulator designed for ECG performance testing. Capable of adding noise, respiration and lead-off simulations. Flexible operation modes for standalone or PC software.
Suitable for R&D and compliance testing.
Compliant with IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, GB 9706.225, GB 9706.227, YY 9706.247, YY1079, YY1139, YY0782, YY0885, JJG 760, JJG 1042, ANSI/AAMI EC11, ANSI/AAMI EC13

Key Features

  • Built-in test circuits as defined in ECG standards
  • Adjustable parameters and selectable options enable to verify DUT with flexibility
  • Provides NST noise simulation - Electrode Motion Artifact / Muscle Noise / Baseline Wander
  • Various signal simulations - Impedance Type Respiration, Wave Modulation Type (Baseline / Amplitude / Frequency) Respiration and lead-off simulation
  • Auto Sequence function assists in conducting semi-automated tests
  • Loads and plays recorded or programmed waveforms
  • Software Development Kit (SDK) allows to develop customized or automated test software with less efforts
  • Optional Standard Assistant software pack simplifies the medical standard with test sequences, options, parameters and pass criterions

CMRR 3.0+

The CMRR tester combining accuracy, convenience and test automation all together.
Compliant with IEC 60601-2-25, IEC 60601-2-27, IEC 60601-2-47, IEC 60601-2-26, YY1079, YY1139, YY0782, YY0885, ANSI / AAMI EC11, ANSI / AAMI EC13.
Applicable for R&D, compliance and production line testing.

Key Features

  • CMRR Tester designed for diagnostic ECG, monitoring ECG, ambulatory ECG and EEG monitor
  • Extreme shielding structure to avoid internal and external noise interference
  • Built-in calibrated sine wave generator and Vc voltage measuring circuit to assure output accuracy level
  • Exclusive shielding covers can be added for higher CMRR requirement
  • Touch screen maximizes the test efficiency in standalone operation
  • PC software operation allows to control and conduct test via mouse clicks
  • Optional Standard Assistant software pack simplifies the medical standard with test sequences, options, parameters and pass criterions
  • Software Development Kit (SDK) assists user to develop customized or automated test software with less efforts.

CMRR 3.0E

The EEG CMRR tester combining accuracy, convenience and test automation all together.
Compliant with IEC80601-2-26:2019 and applicable for R&D, compliance and production run testing.

Key Features

  • Designed for EEG CMRR and system noise testing
  • Extreme shielding structure to avoid internal and external noise interference
  • Built-in calibrated sine wave generator and Vc voltage measuring circuit to assure output accuracy level
  • Exclusive shielding covers can be added for higher CMRR requirement
  • Touch screen maximizes the test efficiency in standalone operation
  • PC software operation allows to control and conduct test via mouse clicks
  • Optional Standard Assistant software pack simplifies the medical standard with test sequences, options, parameters and pass criterions
  • Software Development Kit (SDK) assists user to develop customized or automated test software with less efforts

SEEG 100E

The EEG performance tester is compliant with the test requirements of IEC 80601-2-26:2019 and applicable for R&D, compliance and production line testing.

Key Features

  • Designed for the latest EEG standard IEC 80601-2-26:2019
  • Sophisticated electrical and shielding design enables the test system to output 1μV signal
  • 9 channels with auto-select switches for user to test performance individually
  • Built-in test circuits as defined in EEG standards with selection of 620kΩ/4.7nF for input impedance test
  • Able to load and replay files in PhysioNet’s EDF format, binary format and text format
  • IEC 80601-2-26 helper simplifies the medical standard with test sequences, options, parameters and pass criterions
  • Software Development Kit (SDK) assists user to develop customized or automated test software with less efforts

AECG100

The Innovative simulator to output ECG and PPG analog signals simultaneously.
Adjustable time difference parameters to generate various Pulse Wave Transit Time (PWTT) signals.
Standard Coverage: IEC 60601-2-47, YY 0885, YY 9706.247.
Applicable for R&D, compliance and production line testing

Key Features

  • AECG100 main console unit includes ECG module with built-in test circuits with auto select switches per ECG standard required
  • PPG-1R-525 module offers optical waveforms simulating PPG heart rate signals
  • PPG-2R-880 and PPG-2R-940 module offer red and infrared optical waveforms for SpO2 testing
  • Adjustable PWTT parameters allows user to check and improve the algorithm of blood pressure applications
  • Developing R curves of device under test (DUT) for SpO2 monitors’ verification and validation testing
  • Test parameters in each test mode can be saved and integrated as a series of customized test sequences for improving the testing efficiency
  • Waveform player function reproduces and repeats recorded or programmed waveforms
  • AECG Assistant software pack simplifies test sequences of medical standards into adjustable parameters, selectable options, test procedures and pass criterion
  • Software Development Kit (SDK) assists user to develop customized or automated test software with less efforts

DFS200 Defibrillator and AED Tester

It comes with various ECG patterns for AED defibrillation tests and an embedded battery voltage multimeter. The main features are data retrieval and routine creation. It can manage a complete history of every measurement the user has made in the device, including AED test results, date and time, along with user notes. With AIMS CMS for synchronization management, it is responsible for work order viewing, work order tracking, path planning, etc.

Key Features

  • Defibrillation energy test range: up to 600 joules and 5000Vpp
  • Set adult vs pediatric defibrillation passing range
  • Embedded battery voltage multimeter
  • Every measurement recorded
  • Arbitrary connection without distinguishing polarity
  • The product is only 330g and can be operated with one hand
  • Plenty of air outlet improve heat dissipation and dust-proof
  • Available ECG waves: VF coarse, VF fine, VT fast, VT, AFib, Asystole, NSR
  • Compatible Defibrillation Waveform: Biphasic Waveform (Rectilinear Biphasic Waveform, Biphasic Truncated Exponential Waveform, Pulsed Biphasic Waveform), Monophasic Waveform
  • Applicable to all AED brands
  • Detachable cables for easy storage
  • Voltage : Up to 5000 Vp_Accuracy : ± (1% of reading + 2V), typical
  • Standalone device operates for simple tests
  • The optional paddle box set has outstanding electrical conductivity and mechanical characteristics. The conductive gel drainage grooves are designed for easy cleaning

Related Products